{"id":8767,"date":"2020-08-11T05:43:00","date_gmt":"2020-08-11T05:43:00","guid":{"rendered":"https:\/\/symphonyventicool.com\/blogs\/?p=8767"},"modified":"2026-08-11T07:47:55","modified_gmt":"2026-08-11T07:47:55","slug":"how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories","status":"publish","type":"post","link":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/","title":{"rendered":"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8767\" class=\"elementor elementor-8767\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f058bf0 e-flex e-con-boxed e-con e-parent\" data-id=\"f058bf0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6729909 elementor-widget elementor-widget-heading\" data-id=\"6729909\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_81 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#How_to_Size_Industrial_Swamp_Coolers_for_High-Ceiling_Spaces\" >How to Size Industrial Swamp Coolers for High-Ceiling Spaces?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#What_Is_Swamp_Cooler_Sizing_and_Why_Ceiling_Height_Matters\" >What Is Swamp Cooler Sizing and Why Ceiling Height Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#How_Warehouse_Volume_Is_Calculated_for_Cooling\" >How Warehouse Volume Is Calculated for Cooling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#The_CFM_Formula_for_Evaporative_Cooler_Sizing\" >The CFM Formula for Evaporative Cooler Sizing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Air_Changes_Per_Hour_Explained_for_Industrial_Spaces\" >Air Changes Per Hour Explained for Industrial Spaces<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#How_Ceiling_Height_Changes_Airflow_Requirements\" >How Ceiling Height Changes Airflow Requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Example_10000_Square_Foot_Facility_at_Different_Ceiling_Heights\" >Example: 10000 Square Foot Facility at Different Ceiling Heights<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Effective_Cooling_Zone_vs_Full_Building_Volume\" >Effective Cooling Zone vs Full Building Volume<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Additional_Factors_Beyond_Ceiling_Height\" >Additional Factors Beyond Ceiling Height<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#How_to_Calculate_Swamp_Cooler_Size_for_a_Facility_Step_by_Step\" >How to Calculate Swamp Cooler Size for a Facility: Step by Step<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Choosing_the_Right_Symphony_Venticool_System_for_High_Ceiling_Spaces\" >Choosing the Right Symphony Venticool System for High Ceiling Spaces<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Common_Sizing_Mistakes_to_Avoid\" >Common Sizing Mistakes to Avoid<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_to_Size_Industrial_Swamp_Coolers_for_High-Ceiling_Spaces\"><\/span>How to Size Industrial Swamp Coolers for High-Ceiling Spaces?<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6b8130 elementor-widget elementor-widget-text-editor\" data-id=\"f6b8130\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>A common sizing mistake in industrial evaporative cooling is calculating airflow needs from floor area alone, without accounting for ceiling height. Two warehouses with identical floor plans but different roof heights need very different airflow capacity to achieve the same cooling effect, and getting this wrong leads to underpowered systems that never quite bring the temperature down. This guide breaks down how ceiling height factors into swamp cooler sizing, the formulas used to calculate airflow correctly, and how to apply this when planning an industrial cooling system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd40223 e-flex e-con-boxed e-con e-parent\" data-id=\"fd40223\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-03621d0 elementor-widget elementor-widget-heading\" data-id=\"03621d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"What_Is_Swamp_Cooler_Sizing_and_Why_Ceiling_Height_Matters\"><\/span>What Is Swamp Cooler Sizing and Why Ceiling Height Matters<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e340e43 elementor-widget elementor-widget-text-editor\" data-id=\"e340e43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Swamp cooler sizing, also called evaporative cooler sizing, is the process of matching a cooling unit&#8217;s airflow output to the volume of air that needs to be cooled and refreshed within a given time. Because air occupies three dimensions, floor area alone only tells part of the story. A factory with a 12 foot ceiling and one with a 30 foot ceiling covering the same floor space contain very different volumes of air, and the taller space requires proportionally more airflow to achieve the same rate of cooling.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d79a6 e-flex e-con-boxed e-con e-parent\" data-id=\"61d79a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-d6de37e e-con-full cta_container e-flex e-con e-child\" data-id=\"d6de37e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-69e5460 cta_text elementor-widget elementor-widget-heading\" data-id=\"69e5460\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Call Now for Quick Support<\/span>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-567af68 elementor-align-center elementor-widget__width-initial elementor-widget elementor-widget-button\" data-id=\"567af68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"tel:+916354914487\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Call Us Now!<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-930c987 e-flex e-con-boxed e-con e-parent\" data-id=\"930c987\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6896817 elementor-widget elementor-widget-heading\" data-id=\"6896817\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_Warehouse_Volume_Is_Calculated_for_Cooling\"><\/span>How Warehouse Volume Is Calculated for Cooling<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17772a6 elementor-widget elementor-widget-text-editor\" data-id=\"17772a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Cooling capacity for large industrial spaces is based on air volume, calculated as floor area multiplied by ceiling height, expressed in cubic feet or cubic meters.<\/p><ul><li>Volume in cubic feet equals length multiplied by width multiplied by average ceiling height.<\/li><li>For spaces with uneven rooflines, such as sloped or trussed ceilings, an average height is typically used for a reasonable estimate.<\/li><li>This volume figure becomes the basis for calculating how much airflow is needed to achieve the target number of air changes per hour.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-caac6ec e-flex e-con-boxed e-con e-parent\" data-id=\"caac6ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-916e497 elementor-widget elementor-widget-heading\" data-id=\"916e497\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"The_CFM_Formula_for_Evaporative_Cooler_Sizing\"><\/span>The CFM Formula for Evaporative Cooler Sizing<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32a1e58 elementor-widget elementor-widget-text-editor\" data-id=\"32a1e58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Airflow requirement is generally calculated using building volume and a target air change rate, following an approach consistent with guidance published by the United States Department of Energy&#8217;s Building America Solution Center for evaporative cooling system sizing.<\/p><ul><li>Required airflow equals building volume in cubic feet multiplied by the target air changes per hour, divided by sixty, giving the result in cubic feet per minute.<\/li><li>In metric terms, required airflow in cubic meters per hour equals building volume in cubic meters multiplied directly by the target air change rate.<\/li><li>A simplified rule of thumb sometimes used for quick estimates is floor area multiplied by ceiling height, divided by two, though a full volume and air change rate calculation gives a more reliable figure for industrial spaces.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-11e6510 e-flex e-con-boxed e-con e-parent\" data-id=\"11e6510\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-52017a0 elementor-widget elementor-widget-image\" data-id=\"52017a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1050\" height=\"520\" src=\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Air-Changes-Per-Hour-Explained-for-Industrial-Spaces.png\" class=\"attachment-full size-full wp-image-8813\" alt=\"\" srcset=\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Air-Changes-Per-Hour-Explained-for-Industrial-Spaces.png 1050w, https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Air-Changes-Per-Hour-Explained-for-Industrial-Spaces-768x380.png 768w, https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Air-Changes-Per-Hour-Explained-for-Industrial-Spaces-150x74.png 150w\" sizes=\"(max-width: 1050px) 100vw, 1050px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-16f88e9 e-flex e-con-boxed e-con e-parent\" data-id=\"16f88e9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2845bb2 elementor-widget elementor-widget-heading\" data-id=\"2845bb2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Air_Changes_Per_Hour_Explained_for_Industrial_Spaces\"><\/span>Air Changes Per Hour Explained for Industrial Spaces<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df28420 elementor-widget elementor-widget-text-editor\" data-id=\"df28420\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Air changes per hour, commonly written as ACH, describes how many times the full volume of air in a space is replaced with fresh air in one hour. Industrial facilities generally need a higher ACH than offices or homes because of equipment heat, occupancy density, and process related fumes or humidity.<\/p><ul><li>General warehouse spaces typically target somewhere in the range of fifteen to thirty air changes per hour, depending on internal heat load and local climate.<\/li><li>Loading docks and areas with vehicle exhaust often need a higher air change rate to dilute fumes effectively.<\/li><li>Ventilation guidance referenced in ASHRAE Standard 62.1 provides general minimum ventilation principles that many industrial cooling calculations are built around, alongside facility specific heat load assessments.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ded4d8d e-flex e-con-boxed e-con e-parent\" data-id=\"ded4d8d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e7a17dd elementor-widget elementor-widget-heading\" data-id=\"e7a17dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_Ceiling_Height_Changes_Airflow_Requirements\"><\/span>How Ceiling Height Changes Airflow Requirements<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b8f3bf elementor-widget elementor-widget-text-editor\" data-id=\"6b8f3bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Because volume scales directly with height, increasing ceiling height while keeping floor area and target air change rate constant increases the required airflow by the same proportion. A factory that doubles its ceiling height, for the same floor area and desired air change rate, needs roughly double the airflow capacity to maintain equivalent cooling performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-13a33c0 e-flex e-con-boxed e-con e-parent\" data-id=\"13a33c0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d3cbe0 elementor-widget elementor-widget-heading\" data-id=\"4d3cbe0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Example_10000_Square_Foot_Facility_at_Different_Ceiling_Heights\"><\/span>Example: 10000 Square Foot Facility at Different Ceiling Heights<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a601a36 elementor-widget elementor-widget-text-editor\" data-id=\"a601a36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<table width=\"600\">\n<tbody>\n<tr>\n<td style=\"background-color: #007dcc; color: white; border: 1px solid black;\"><strong>Ceiling Height<\/strong><\/td>\n<td style=\"background-color: #007dcc; color: white; border: 1px solid black;\"><strong>Building Volume<\/strong><\/td>\n<td style=\"background-color: #007dcc; color: white; border: 1px solid black;\"><strong>Approximate CFM at 20 ACH<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"167\">12 feet<\/td>\n<td width=\"200\">120000 cubic feet<\/td>\n<td width=\"233\">About 40000 CFM<\/td>\n<\/tr>\n<tr>\n<td width=\"167\">20 feet<\/td>\n<td width=\"200\">200000 cubic feet<\/td>\n<td width=\"233\">About 66700 CFM<\/td>\n<\/tr>\n<tr>\n<td width=\"167\">30 feet<\/td>\n<td width=\"200\">300000 cubic feet<\/td>\n<td width=\"233\">About 100000 CFM<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nThese figures illustrate the general relationship between height and airflow demand rather than an exact specification for any single facility, since actual requirements also depend on heat load, insulation, and local climate conditions.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1663556 e-flex e-con-boxed e-con e-parent\" data-id=\"1663556\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c153c2 elementor-widget elementor-widget-heading\" data-id=\"5c153c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Effective_Cooling_Zone_vs_Full_Building_Volume\"><\/span>Effective Cooling Zone vs Full Building Volume<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06cda5c elementor-widget elementor-widget-text-editor\" data-id=\"06cda5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In very high bay warehouses, cooling the entire volume from floor to roof is often unnecessary and inefficient, since workers and machinery occupy only the lower portion of the space. Many industrial cooling designs instead target an effective cooling zone, typically the lower eight to twelve feet where people and equipment are actually located, rather than the full ceiling height.<\/p><ul><li>Calculating airflow based on the effective occupied zone rather than total building volume can meaningfully reduce the required CFM for very tall structures.<\/li><li>Air distribution through ducting and directional diffusers helps concentrate cooled air where it is needed, rather than allowing it to rise and dissipate near a high roofline.<\/li><li>This approach works best when combined with proper duct placement and outlet positioning, since simply running a larger unit without directing airflow can still waste cooling capacity into unused overhead space.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc7d2ef e-flex e-con-boxed e-con e-parent\" data-id=\"dc7d2ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7654675 elementor-widget elementor-widget-heading\" data-id=\"7654675\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Additional_Factors_Beyond_Ceiling_Height\"><\/span>Additional Factors Beyond Ceiling Height<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-308a4c7 elementor-widget elementor-widget-text-editor\" data-id=\"308a4c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Internal heat load from machinery, ovens, or production processes increases the required air change rate beyond the general baseline.<\/li><li>Roof and wall insulation quality affects how quickly heat builds up inside the space, influencing both cooling load and air change targets.<\/li><li>Number of occupants and their activity level adds to the heat and humidity load that cooling airflow needs to offset.<\/li><li>Open bay doors, loading docks, and skylights all change how a space gains heat and should be factored into the sizing conversation.<\/li><li>Local climate, particularly ambient humidity, affects evaporative cooling performance, since evaporative systems work best in drier climates.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0daf135 e-flex e-con-boxed e-con e-parent\" data-id=\"0daf135\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b9011dc elementor-widget elementor-widget-image\" data-id=\"b9011dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1050\" height=\"520\" src=\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Calculate-Swamp-Cooler-Size-Facility.png\" class=\"attachment-large size-large wp-image-8817\" alt=\"\" srcset=\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Calculate-Swamp-Cooler-Size-Facility.png 1050w, https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Calculate-Swamp-Cooler-Size-Facility-768x380.png 768w, https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Calculate-Swamp-Cooler-Size-Facility-150x74.png 150w\" sizes=\"(max-width: 1050px) 100vw, 1050px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c1c5e2 e-flex e-con-boxed e-con e-parent\" data-id=\"0c1c5e2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e0e2110 elementor-widget elementor-widget-heading\" data-id=\"e0e2110\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_to_Calculate_Swamp_Cooler_Size_for_a_Facility_Step_by_Step\"><\/span>How to Calculate Swamp Cooler Size for a Facility: Step by Step<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd3d50 elementor-widget elementor-widget-text-editor\" data-id=\"fcd3d50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Measure the floor area and average ceiling height of the space to calculate total building volume in cubic feet or cubic meters.<\/li><li>Decide whether to size for the full building volume or an effective occupied zone, particularly relevant for high bay spaces above twenty feet.<\/li><li>Select a target air change rate appropriate for the facility type, adjusting upward for high heat load areas such as loading docks or production floors.<\/li><li>Calculate required airflow using volume multiplied by target ACH, divided by sixty for a result in CFM.<\/li><li>Compare the calculated requirement against the rated airflow of available industrial ducted coolers to determine the number of units needed.<\/li><li>Plan duct layout and outlet placement to direct airflow toward the occupied zone rather than allowing it to disperse into unused overhead volume.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-acf0102 e-flex e-con-boxed e-con e-parent\" data-id=\"acf0102\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-844ada2 elementor-widget elementor-widget-heading\" data-id=\"844ada2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Choosing_the_Right_Symphony_Venticool_System_for_High_Ceiling_Spaces\"><\/span>Choosing the Right Symphony Venticool System for High Ceiling Spaces<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8f407d elementor-widget elementor-widget-text-editor\" data-id=\"e8f407d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Symphony Venticool offers a range of industrial ducting coolers with different airflow ratings and duct length capacities, which allows a facility to be sized based on actual calculated CFM rather than a single fixed unit. For high ceiling factories and warehouses, the ability to connect ducting and multiple outlet grills helps direct cooled air specifically toward the occupied zone rather than losing cooling effect into open overhead space. Facilities planning a new installation or evaluating whether an existing system is undersized for their ceiling height can reach out to Symphony Venticool for a sizing assessment based on their specific floor area, height, and layout.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c359fc e-flex e-con-boxed e-con e-parent\" data-id=\"4c359fc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7492f94 e-con-full cta_container e-flex e-con e-child\" data-id=\"7492f94\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0ccb11a cta_text elementor-widget elementor-widget-heading\" data-id=\"0ccb11a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Email Us for a Quick Response<\/span>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d1c3b2 elementor-align-center elementor-widget__width-initial elementor-widget elementor-widget-button\" data-id=\"4d1c3b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"mailto:industrial@symphonylimited.com\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Email Us Now!<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4b4525d e-flex e-con-boxed e-con e-parent\" data-id=\"4b4525d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cb0f270 elementor-widget elementor-widget-heading\" data-id=\"cb0f270\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Common_Sizing_Mistakes_to_Avoid\"><\/span>Common Sizing Mistakes to Avoid<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-706c188 elementor-widget elementor-widget-text-editor\" data-id=\"706c188\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Sizing a cooler based on floor area alone without factoring in ceiling height or total building volume.<\/li><li>Applying a standard air change rate without adjusting for higher heat load areas such as production zones or loading docks.<\/li><li>Attempting to cool the full volume of a very high bay space instead of targeting the effective occupied zone with directed ducting.<\/li><li>Ignoring open doors, skylights, or poor insulation, which increase the actual cooling load beyond the basic volume calculation.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-73c3252 e-flex e-con-boxed e-con e-parent\" data-id=\"73c3252\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e872a6 elementor-widget elementor-widget-heading\" data-id=\"6e872a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-abb48a2 elementor-widget elementor-widget-shortcode\" data-id=\"abb48a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">        <style type=\"text\/css\">\n        \t        \t.thfaqf-tab h3.thfaqf-tablinks-8773.active {\n\t\t\t    background-color: #f5f5f5!important;\n\t\t\t    color: #f5f5f5!important;\n\t\t\t}\n\t\t\t.thfaqf-tab h3.thfaqf-tablinks-8773:hover {\n\t\t\t  \tbackground-color: #f5f5f5!important;\n\t\t\t}\n\t\t    .thfaqf-faq-item-8773.thfaqf-active .thfaqf-title-text{\n\t\t\t\tcolor: #ffffff!important;\n\t\t\t}\n          \n        <\/style>\n       \t\t<div class=\"thfaqf-faq-list thfaqf-theme-wrapper-hello-elementor\">\n            <h3 class=\"thfaqf-faq-list-title\">How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories<\/h3><div class=\"faq-item-wrapper\">\t\t<div id=\"thfaqf-faq-item-8773_0\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-active thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >Does ceiling height affect industrial air cooler sizing?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>Yes, ceiling height has a major effect on sizing, since cooling requirements are based on total building volume rather than floor area alone. A taller ceiling means more air volume to cool, which increases the required airflow to reach the same air change rate.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"0\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t\t\t<div id=\"thfaqf-faq-item-8773_1\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >How do you calculate the correct swamp cooler size for a warehouse?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>Calculate the building volume by multiplying floor area by average ceiling height, choose a target air change rate suited to the facility type, then multiply volume by that rate and divide by sixty to get the required airflow in CFM.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"1\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t\t\t<div id=\"thfaqf-faq-item-8773_2\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >What air change rate should a factory or warehouse target?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>Most industrial spaces target somewhere between fifteen and thirty air changes per hour, with higher rates needed for areas with significant heat generating equipment, vehicle exhaust, or process related fumes.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"2\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t\t\t<div id=\"thfaqf-faq-item-8773_3\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >How many CFM does a high bay warehouse need compared to a standard ceiling?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>A high bay warehouse with a ceiling roughly double the height of a standard facility, at the same floor area and target air change rate, generally needs close to double the airflow capacity, since building volume scales directly with height.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"3\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t\t\t<div id=\"thfaqf-faq-item-8773_4\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >Should you cool the full height of a very tall warehouse?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>Not always. For very high bay spaces, many industrial cooling designs target only the effective occupied zone, usually the lower eight to twelve feet, using directed ducting rather than attempting to cool the entire volume up to the roofline.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"4\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t\t\t<div id=\"thfaqf-faq-item-8773_5\" class=\"thfaqf-faq-item  thfaqf-faq-item-8773    thfaqf-post-id-8773 thfaqf-count-dsply-setngs\" style=\"border-radius: 6px;\" >\n\t\t\t<div data-active_color=\"#ffffff\" class=\"thfaqf-faq-item-title\" style=\"border-width: 1px; border-style: solid; margin-bottom: -1px; background-color: #f3f3f3; border-color: #f3f3f3;\">\n \t\t\t\t<h4>\n \t\t\t\t\t \t\t\t\t<span class=\"thfaq-marker thfaqf-toggle-icon\" style=\" color: #007dcc;\"><\/span>\n \t\t\t\t\t<span class=\"thfaqf-title-text \" style=\" color: #000000;\" >Can one industrial cooler size fit every ceiling height?<\/span>\n \t\t\t\t<\/h4>\t\n\t\t\t<\/div>\n\t\t\t<div class=\"thfaqf-faq-item-content\" style=\"border-width: 1px; border-style: solid; background-color: #ffffff; border-color: #ffffff; color: #000000;\" >\n\t\t\t\t<p>No, a single fixed sizing rule does not work across different ceiling heights, since building volume changes significantly with height even at the same floor area. Sizing should always be based on the specific volume or effective cooling zone of each facility.<\/p>\n\t\t\t\t<div class=\"thfaq-enable-comment-box thfaqf-hide\"> <p>\t\t<div class=\"thfaqf-comment-wrapper\">\n\t\t\t<form form method=\"post\" class=\"thfaqf-post-comment\">\n\t\t\t\t<p><input class=\"thfaqf-comment-box thfaqf-uname\" type=\"text\" placeholder=\"Name...\"name=\"user_name\"\/><\/p>\n\t\t\t\t<p class=\"threq-name\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"action\" value=\"thfaqf_comment\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_id\" value=\"8773\">\n\t\t\t\t<input type=\"hidden\" name=\"faq_index\"value=\"5\">\n\t\t\t\t<p><textarea placeholder=\"Add a Comment...\"name=\"user_msg\" class=\"thfaqf-comment-box thfaqf-ucomment\"><\/textarea><\/p>\n\t\t\t\t<p class=\"threq-comment\"><\/p>\n\t\t\t\t<input type=\"hidden\" name=\"wp_thfaqc_nonce\" value=\"8ebe5c2ecd\"\/>\n\t\t    \t<p><button type=\"submit\" name=\"thfaqf_comment_submt\" class=\"thfaqf-submt-cmmt button primary is-xsmall\" onclick=\"submitFaqfComment(this)\">Send<\/button><\/p><p class=\"thfaqf-comment-validetion\"><\/p>\n\t\t    <\/form>\t\n\n\t\t    \t\t<\/div>\n\t\t <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"log\"><\/div>\n\t\t<\/div>\n \t\t<\/div>\t        <p class=\"thfaqf-display-faq-setngs hide-faqf-group\">\n\t\t\t\t<span class=\"thfaqf-pagination\">\n\t\t\t\t\t<span onclick=\"ThfaqPagination(this,'prev_page')\" ><a class=\"thfaqf-prev-page thfaqf-div-none\"  href=\"#\"><<<\/a><\/span>\t\n\t\t\t\t\t\t\t\t            <span class=\"thfaqf-page-no \" data-number=\"1\">\n\t\t\t           \t<a class=\"thfaqf-pnumber thfaq-ft current\"href=\"#\" onclick=\"ThfaqEachPage(this)\" >1<\/a>\n\t\t\t            <\/span>\n\t\t\t             \n\t\t        \t<span onclick=\"ThfaqPagination(this,'next_page')\" data-page_count=\"1\"><a class=\"thfaqf-next-page thfaqf-div-none\" href=\"#\">>><\/a><\/span>\t\n\t\t\t\t<\/span>\n\t\t\t\t<input type=\"hidden\" class=\"thfaqf-count-faq-number\"name=\"count_faq\" value=\"6\"\/>\n\t\t\t<\/p><br>\n            \t    <\/div>\n\t    <\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d34bcb e-flex e-con-boxed e-con e-parent\" data-id=\"7d34bcb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1d3f774 elementor-widget elementor-widget-heading\" data-id=\"1d3f774\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0747a2a elementor-widget elementor-widget-text-editor\" data-id=\"0747a2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Ceiling height is one of the most overlooked variables in industrial evaporative cooler sizing, yet it has a direct, proportional effect on the airflow a facility actually needs. Calculating cooling requirements from building volume, applying an appropriate air change rate, and targeting the effective occupied zone in very high spaces all lead to a far more accurate sizing outcome than floor area estimates alone.<\/p><p>Symphony Venticool&#8217;s ducted industrial cooler range can be configured with duct length and outlet placement suited to different ceiling heights, helping facilities direct cooling where it is actually needed. Reach out to Symphony Venticool for a sizing assessment based on your specific floor area, ceiling height, and layout.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d60e4a e-flex e-con-boxed e-con e-parent\" data-id=\"7d60e4a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-da79dee elementor-widget elementor-widget-video\" data-id=\"da79dee\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/youtu.be\\\/nrl_PJFQadA?si=gaKzbZvEGEqjLUnH&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Swamp cooler sizing for a warehouse or factory depends on building volume, not floor area alone, which is why ceiling height has a direct and often underestimated impact on the airflow capacity required. Taller spaces hold significantly more air, so the same floor area at 30 feet high can need more than twice the airflow, measured in CFM or CMH, compared to a 12 foot ceiling. This guide explains how to calculate correct evaporative cooler sizing using volume and air change rate, how ceiling height changes that calculation, and how Symphony Venticool ducted systems can be configured for high ceiling industrial spaces.<\/p>\n","protected":false},"author":1,"featured_media":8805,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[10],"tags":[],"class_list":["post-8767","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-air-cooler"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories\" \/>\n<meta property=\"og:description\" content=\"Swamp cooler sizing for a warehouse or factory depends on building volume, not floor area alone, which is why ceiling height has a direct and often underestimated impact on the airflow capacity required. Taller spaces hold significantly more air, so the same floor area at 30 feet high can need more than twice the airflow, measured in CFM or CMH, compared to a 12 foot ceiling. This guide explains how to calculate correct evaporative cooler sizing using volume and air change rate, how ceiling height changes that calculation, and how Symphony Venticool ducted systems can be configured for high ceiling industrial spaces.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/\" \/>\n<meta property=\"og:site_name\" content=\"Symphony Venticool\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-11T05:43:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-11T07:47:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1050\" \/>\n\t<meta property=\"og:image:height\" content=\"520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Maulik Solanki (MarCom Manager - Symphony Limited)\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Maulik Solanki (MarCom Manager - Symphony Limited)\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/\",\"url\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/\",\"name\":\"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories\",\"isPartOf\":{\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png\",\"datePublished\":\"2020-08-11T05:43:00+00:00\",\"dateModified\":\"2026-08-11T07:47:55+00:00\",\"author\":{\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/#\/schema\/person\/85392067a884d3908abe1dcc11083e83\"},\"breadcrumb\":{\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage\",\"url\":\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png\",\"contentUrl\":\"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png\",\"width\":1050,\"height\":520},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/symphonyventicool.com\/blogs\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/symphonyventicool.com\/blogs\/#website\",\"url\":\"https:\/\/symphonyventicool.com\/blogs\/\",\"name\":\"Symphony Venticool\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/symphonyventicool.com\/blogs\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/","og_locale":"en_US","og_type":"article","og_title":"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories","og_description":"Swamp cooler sizing for a warehouse or factory depends on building volume, not floor area alone, which is why ceiling height has a direct and often underestimated impact on the airflow capacity required. Taller spaces hold significantly more air, so the same floor area at 30 feet high can need more than twice the airflow, measured in CFM or CMH, compared to a 12 foot ceiling. This guide explains how to calculate correct evaporative cooler sizing using volume and air change rate, how ceiling height changes that calculation, and how Symphony Venticool ducted systems can be configured for high ceiling industrial spaces.","og_url":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/","og_site_name":"Symphony Venticool","article_published_time":"2020-08-11T05:43:00+00:00","article_modified_time":"2026-08-11T07:47:55+00:00","og_image":[{"width":1050,"height":520,"url":"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png","type":"image\/png"}],"author":"Maulik Solanki (MarCom Manager - Symphony Limited)","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Maulik Solanki (MarCom Manager - Symphony Limited)","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/","url":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/","name":"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories","isPartOf":{"@id":"https:\/\/symphonyventicool.com\/blogs\/#website"},"primaryImageOfPage":{"@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage"},"image":{"@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage"},"thumbnailUrl":"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png","datePublished":"2020-08-11T05:43:00+00:00","dateModified":"2026-08-11T07:47:55+00:00","author":{"@id":"https:\/\/symphonyventicool.com\/blogs\/#\/schema\/person\/85392067a884d3908abe1dcc11083e83"},"breadcrumb":{"@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#primaryimage","url":"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png","contentUrl":"https:\/\/symphonyventicool.com\/blogs\/wp-content\/uploads\/2026\/08\/Ceiling-Height-Changes-Swamp-Cooler-Sizing-Warehouses-Factories.png","width":1050,"height":520},{"@type":"BreadcrumbList","@id":"https:\/\/symphonyventicool.com\/blogs\/how-ceiling-height-changes-swamp-cooler-sizing-in-warehouses-and-factories\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/symphonyventicool.com\/blogs\/"},{"@type":"ListItem","position":2,"name":"How Ceiling Height Changes Swamp Cooler Sizing in Warehouses and Factories"}]},{"@type":"WebSite","@id":"https:\/\/symphonyventicool.com\/blogs\/#website","url":"https:\/\/symphonyventicool.com\/blogs\/","name":"Symphony Venticool","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/symphonyventicool.com\/blogs\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/posts\/8767","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/comments?post=8767"}],"version-history":[{"count":47,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/posts\/8767\/revisions"}],"predecessor-version":[{"id":8853,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/posts\/8767\/revisions\/8853"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/media\/8805"}],"wp:attachment":[{"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/media?parent=8767"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/categories?post=8767"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/symphonyventicool.com\/blogs\/wp-json\/wp\/v2\/tags?post=8767"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}